Work backward from your contract deadline to allow time for closed-house preparation, testing, pickup, and the report.

Work backward from the decision deadline

Find the date and time by which your contract requires an inspection response, not just the closing date. Ask your agent about the deadline and arrange a qualified radon tester as soon as the seller permits access. Confirm the testing method, required conditions, placement, pickup, and report delivery with the tester and your state radon office.

EPA recommends testing the lowest level that could be used regularly. For a test lasting less than four days, ask the seller and occupants to maintain closed-house conditions starting at least 12 hours before placement and throughout testing. Keep windows and exterior doors closed except for normal entry and exit. Have the tester confirm the ventilation settings. Avoid running fans or machines that draw outdoor air in. An existing radon-reduction fan should keep running, and small exhaust fans may run briefly.

An example schedule

Suppose your response deadline is Friday at 5 p.m., the house is not already in closed-house conditions, and your selected tester confirms a 48-hour continuous-monitor test. Begin closed-house conditions no later than Tuesday at 8 p.m.; place the monitor Wednesday at 8 a.m.; maintain the conditions until the earliest completion and pickup Friday at 8 a.m. That is 12 hours of preparation plus 48 hours of measurement before pickup, not including report delivery or time to respond.

PreFlight Home Inspections in Metro Detroit says it collects its monitor after at least 48 hours and sends the report the same day as pickup. That is this provider's stated practice, not a guaranteed delivery time for every booking. For the example, confirm a specific Friday delivery time with the tester and leave enough time to read the report and contact your agent before 5 p.m. Arrange earlier if that cannot be confirmed. A different tester or method may need more time, including laboratory processing.

If only 48 hours remain and closed-house preparation has not begun, a 12-hour setup plus a 48-hour test already exceeds the available time. Ask your agent about the contract deadline and whether the parties can agree to more time; do not shorten the required test to fit.

Use the result

For the continuous-monitor test in this example, use the reported average over at least 48 hours. If the tester uses two short-term passive tests under EPA’s transaction protocol, use the average of those two results. EPA recommends fixing a home at 4 pCi/L or higher and considering mitigation between 2 and 4 pCi/L. Ask the tester about any interference or limitations. Share the written report with your agent before the contract deadline.

If mitigation is being considered, give qualified contractors the test report and ask for written bids that describe the system, installation, and who arranges and pays for post-installation testing. The mitigation guide helps you compare those scopes.